Soccer
Home > Application Guide > Outdoor > Soccer
Lighting design criteria
- Strong flash of light momentarily to exclude as much as possible and the players the glare off of the glare off of the game by minimizing design should be.
- The luminance criteria should be designed to suite the competition level and purpose.
- Shadows and inadequate vertical plane luminance impede athletes and spectators and these issues should be solved through the design.
- The design must prevent light pollution by taking account of the surrounding environment.
Recommendation of Minimum Lighting Levels
Sport |
Illuminance Level (Em. Horizontal) Lux * (Non CTV) |
ClassⅠ |
ClassⅡ |
ClassⅢ |
Em Lux |
Uo Min/ave |
Em Lux |
Uo Min/ave |
Em Lux |
Uo Lux |
Soccer |
200 |
0.6 |
100 |
0.5 |
75 |
0.5
|
- ※ EN 12193
- - ClassⅠ: Top Level Competition
- - ClassⅡ: Intermediate Level Competition
- - ClassⅢ: Lower Level Competition & Suspervised Training
- ※ Em is the Maintained Illuminance Level (specification level) and is the design illuminance level, below which the lighting should not be allowed to fall during the period to planned maintenance.